VFBATTERY REPORT

Applications: Battery Energy Storage Systems (BESS)

Pages 137–173 (37 pages)

Battery Report 2024, page 156: Applications: Battery Energy Storage Systems (BESS)
Text on page 156

Control Issues And Integration Challenges Dominate Safety Incidents Rather than Direct Cell Failures INCIDENTS BY TRIGGERING COMPONENT

ROOT CAUSES OF INCIDENTS

BOS Balance of System

Control issues are triggering many incidents: While only 11% of incidents were directly attributed to cell failures, many more were indirectly caused by cell failures triggered through operation conditions outside of predefined safety windows due to control issues

Issues happen early in the project lifecycle: In about 3 out of 4 cases, events happen during construction, commissioning or within the first 2 years of operation

Integration remains challenging: Integration related issues are the most common root cause of incidents including wiring, coolant systems or safety systems

Source: EPRI

Extracted from the PDF; charts and images may read imperfectly.