Chemistry: Cathode
Pages 203–232 (30 pages)
Text on page 224
LMFP v. LFP STRUCTURE
LMFP partially replaces Fe in LFP with Mn.
Incorporating Mn into the system raises the redox voltage, resulting in increased overall energy density. PERFORMANCE
LMFPʼs capacity at low-temperature performance is more stable compared to LFP.
Both chemistries exhibit similar safety profiles. MARKET/ USAGE
LMFP64 60% Mn content) is the most widely available composition in the market, with research efforts now shifting towards 70% Mn content.
LMFP is often blended with NMC due to its similar voltage, which improves the safety and reduces the cost relative to NMC.
Mn/Fe ratio in LMFP (nominal voltage, practical capacity, energy density) LFP 0% Mn 3.4V
20% Mn* 3.44V
40% Mn 3.48V
60% Mn 3.64V
80% Mn 3.96V
LMP 100%Mn 3.95V
161.0 mAh/g 534.9 Wh/kg
161.7 mAh/g 553.5 Wh/kg
157.4 mAh/g 557.0 Wh/kg
142.4 mAh/g 515.8 Wh/kg
126.3 mAh/g 459.9 Wh/kg
63.0 mAh/g 230.6 Wh/kg
20% Mn: LiMn0.2Fe0.8PO4 Source: Guoyuan Securities, Battery Report 2023 (pg125)
Extracted from the PDF; charts and images may read imperfectly.
Page 224 · 22/30